Which cleaning fluid to use for your process?
Cleaning aluminium or stainless steel plastic injection moulds
Recommended cleaning and drying process (for a high quality finish)

1 | 2 | 3 * | 4 | 5 | 6 |
---|---|---|---|---|---|
RODASTEL 2010 | Tap water rinse | ACID CLEANER No3 | Tap water rinse | DI water rinse | Air drying |
Conc: 50-150 g/l Temp: 50-65°C Time: 2-3 min | Conc: 5-10% Temp: 20-30°C Time: 1-5 min |
* Neutralisation needed
Removing grinding compounds from steel and stainless steel
Recommended cleaning and drying process (for a high quality finish)

Conditioning | Finishing | |||||
---|---|---|---|---|---|---|
1 | 2 | 3 * | 4 | 5 | 6 | |
ACID CLEANER No3 | Tap water rinse | GALVEX 17:30 N | Tap water rinse | Cascade | Hot air drying | |
Conc: 3-5% Temp: 30-40°C Time: 2-3 min | Conc: 2% Temp: 50°C Time: 2-3 min | Demi water | Demi water |
* Temporary film on steel
Removing oils from all metals (for precision mechanical parts)
Spot and tarnish free process for automatic plant

1 * | Cleaning | Finishing | ||||
---|---|---|---|---|---|---|
2 | 3 | 4 | 5 | 6 | 7 | |
DECOSPRAY TM | GALVEX 17:30 N | GALVEX 17:30 N | Tap water rinse | Tap water rinse 2 mins | Demi water with LIFT OUT | Air drying |
Conc: 5-10% Temp: 60-70°C Time: 3-4 min | Conc: 4% Temp: 70°C Time: 3-5 min | Conc: 2% Temp: 70°C Time: 3-5 min |
* An oil separator is necessary for perfect results.
** Use NANOCLEAN 95 in case of large quantities of oil to eliminate without oil separator.
Removing oils from all metals (for micromechanicsm with blind holes)
Recommended cleaning and drying process (closed plant vacuum, continuous distillation)

Oil Removing |
---|
RUBIFIN No4 |
Conc: 100% Temp: 30-50°C Time: 3-10 min |
Removing oils from circular saws
Recommended cleaning and drying process (prior to vacuum metalisation P.V.D))

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
---|---|---|---|---|---|---|---|
GALVEX 17:30 N | GALVEX 17:30 N | Tap water rinse 3 min | Di water rinse 30" | FINISH AID SUP.7 | Di water rinse 2.6 μS 15" | Di water rinse 0.2 μS 15" | Hot air drying 80°C |
Conc: 5% Temp: 70°C Time: 5 min | Conc: 2% Temp: 60°C Time: 3 min | Conc: 0.2% Temp: 20°C * Time: 90 min |
* Make up the bath 'step 5' with demineralised water
Removing polishing compounds and oils from sensitive steel (20AP) in the watch and clock industry
Recommended cleaning and drying process (without any corrosion)

1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
---|---|---|---|---|---|---|---|
GALVEX 17:30 N | GALVEX 17:30 N | Tap water rinse 3 min | GALVEX 17.89 SUPRA | Di water rinse 30°C | Di water rinse 0.2 μS 15" | Di water rinse | Hot air drying 80°C |
Conc: 5% Temp: 70°C Time: 3-5 min | Conc: 4% Temp: 65°C Time: 3-5 min | Conc: 3% Temp: 60°C Time: 3-5 min |
Removing polishing compounds from Brass, Zinc die casting, Aluminium and Silver in the watch and clock industry
Spot and tarnish free process for automatic plant

Cleaning | Finishing | |||||
---|---|---|---|---|---|---|
1 | 2 | 3 | 4 * | 5 | 6 | 7 |
GALVEX 18:01 | GALVEX 18:01 | Tap water rinse 2 min | SUPER HELIT IC | Tap water rinse 2 min | Demi water with LIFT OUT | Air drying |
Conc: 3-5% Temp: 70°C Time: 3-5 min | Conc: 2-4% Temp: 70°C Time: 3-5 min | Conc: 2-3% Temp: 50-60°C Time: 3-5 min |
* Prepare solution with demi. water
Removing polishing compounds from Orthopaedic implants
Recommended cleaning and drying process (for a high quality finish)

Conditioning | Finishing | ||||||
---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 * | 5 | 6 | 7 | |
GALVEX 18:01 | GALVEX 18:01 | Tap water rinse | NGL 17.40 P.SP | Tap water rinse | Cascade | Hot air drying | |
Conc: 3-5% Temp: 70°C Time: 2-3 min | Conc: 2-3% Temp: 70°C Time: 2-3 min | Conc: 20 g/l Temp: 50°C Time: 2-3 min | Demi water | Demi water |
* NGL 17.40 P.SP non pulverulent
Prior to solvent drying Electroplating for GLASS - METAL (with blind holes)
Recommended cleaning and drying process (for a high quality finish)

Ultrasonic preparing bath for aqueous cleaning | Tap water rinse | Fluid T.G.V | Drying - Finishing | ||
---|---|---|---|---|---|
Solvent Drying | |||||
Tempered Forane | Satured vapour zone | ||||
Water | Forane or | Vertrel |
Cleaning of Wafers
Recommended cleaning and drying process (for a high quality finish)

Conditioning | Finishing | ||||||
---|---|---|---|---|---|---|---|
1 | 2 | 3 | 4 | 5 | 6 | Hot air drying | |
GALVEX 17:30 SUP | GALVEX 17:30 SUP | SUPER HELIT IC | Cascade | ||||
Conc: 5% Temp: 50°C Time: 5 min | Conc: 3% Temp: 50°C Time: 5 min | Tap water rinse | Conc: 3% Temp: 60°C Time: 2-3 min | Tap water rinse | Demi water | Demi water |